ABB AO2000-LS25 Product Overview

The ABB AO2000-LS25 is an in-situ laser gas analyzer module designed for continuous process gas measurement in industrial plants. As part of the ABB Advance Optima AO2000 analyzer family, the ABB AO2000-LS25 uses Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology to measure specific gas concentrations directly within process lines, stacks, and reaction chambers without requiring traditional sample extraction and conditioning systems. This direct measurement approach helps improve response speed, reduce maintenance requirements, and provide more reliable process monitoring data.

The ABB AO2000-LS25 belongs to the LS25 laser analyzer series and is designed as an external analyzer module that can be integrated with AO2000 central processing units and industrial communication networks. The system uses a transmitter and receiver arrangement positioned across the measurement path, where the laser scans selected gas absorption wavelengths and calculates concentration based on optical absorption characteristics. The module can be configured for measuring gases such as O₂, CO, CH₄, NH₃, H₂O, CO₂, HCl, H₂S, and other process components depending on application requirements.

In practical industrial environments, the ABB AO2000-LS25 provides a direct solution for emission monitoring, combustion optimization, and process control applications where fast measurement response and stable operation are required. It is suitable for harsh process conditions including high dust exposure, elevated temperatures, pressure variations, and corrosive gas environments when properly configured. For replacement or maintenance projects, engineers should verify gas measurement range, optical path length, purge configuration, communication setup, analyzer firmware, and process installation conditions before commissioning.

Technical Specifications

Parameter Name Parameter Value
Product Model AO2000-LS25
Manufacturer ABB
Product Type In-Situ Laser Gas Analyzer Module
Product Series ABB Advance Optima AO2000 Series
Measurement Technology Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Measurement Principle Single-Line Optical Absorption Spectroscopy
Measurement Method Non-contact Direct Process Measurement
Applicable Gases O₂, CO, CH₄, NH₃, H₂O, CO₂, HCl, H₂S and Others (Configuration Dependent)
Optical Path Length Typically 0.5 to 15 m
Communication Interface RS-232 / Ethernet TCP/IP (Configuration Dependent)
Signal Interface Analog and Digital Process Interfaces
Power Supply 24 VDC / External Power Supply Unit
Installation Method Flange-Mounted In-Situ Installation
Purge System Optical Window Purge Support
Operating Environment Industrial Process Conditions
Protection Rating IP66 Transmitter and Receiver Housing
Certification Options ATEX / IECEx / CSA Versions Available

Main Features and Advantages

Direct in-situ gas measurement design

The ABB AO2000-LS25 measures gas concentration directly in the process environment rather than relying on external sampling systems. This eliminates many common issues associated with sample extraction lines, filters, pumps, and conditioning equipment, improving measurement availability and reducing maintenance workload.

AO2000-LS25

TDLAS measurement technology

The laser-based measurement principle provides selective detection of specific gas absorption lines while reducing interference from other process gases. The ABB AO2000-LS25 uses wavelength scanning and signal processing techniques to calculate gas concentration accurately even in demanding process environments.

Fast response for process optimization

Real-time gas measurement is important for combustion control, emission reduction, and process efficiency improvement. The analyzer provides rapid response compared with many traditional extractive measurement systems, allowing operators and control systems to react quickly to changing process conditions.

Suitable for harsh industrial environments

The ABB AO2000-LS25 is designed for applications involving high temperature, high pressure, dust, and corrosive gases. The optical measurement method avoids direct contact between internal measurement components and the process gas, while purge systems help protect optical windows from contamination.

Flexible integration with automation systems

The analyzer can be integrated into ABB process automation architectures through AO2000 system interfaces and industrial communication options. It can provide measurement values, status information, and diagnostic data for DCS monitoring and process control applications.

Maintenance and replacement considerations

For replacement projects, engineers should confirm the exact gas measurement configuration, optical alignment arrangement, purge requirements, process flange design, communication parameters, and analyzer calibration settings. The LS25 is application-specific, and correct configuration matching is important for reliable measurement performance.

Application Fields

The ABB AO2000-LS25 is widely used in industrial process measurement applications where continuous gas monitoring is required.

In power generation plants, the analyzer is commonly used for combustion monitoring, boiler optimization, and emission control. Measuring oxygen and combustion-related gases helps operators maintain efficient fuel usage while meeting environmental requirements.

In chemical and petrochemical facilities, the ABB AO2000-LS25 supports process monitoring applications involving reaction control, safety monitoring, and gas concentration analysis. Direct measurement capability is valuable in processes where sample handling systems may introduce delays or reliability concerns.

In metal processing and steel plants, the analyzer can monitor combustion processes, furnace atmospheres, and exhaust gases under high-temperature conditions. Its optical measurement method allows operation in environments with significant dust and heat exposure.

Cement production facilities use laser gas analyzers for kiln monitoring, combustion optimization, and emission management. Accurate measurement of process gases helps improve fuel efficiency and maintain stable production conditions.

The ABB AO2000-LS25 is also applied in waste incineration plants, pulp and paper facilities, and industrial energy systems. These industries require continuous monitoring of gases such as oxygen, carbon monoxide, moisture, and other process components to support operational control and regulatory compliance.

Related Products

  • ABB AO2000 Uras26 – Infrared photometer module for multi-component gas analysis applications within the Advance Optima platform.
  • ABB AO2000 Limas21 – UV photometer analyzer module used for measuring gases such as NOx, SO₂, and other components.
  • ABB AO2000 Magnos28 – Paramagnetic oxygen analyzer module for continuous O₂ measurement applications.
  • ABB AO2000 EasyLine EL3000 – Compact process gas analyzer family for industrial measurement tasks.
  • ABB AO2040 – Advance Optima analyzer system housing used for modular analyzer configurations.
  • ABB AO2020 – Rack-mounted AO2000 analyzer platform for centralized process measurement systems.
  • ABB LS25 Transmitter Unit – Optical transmitter component used within the AO2000-LS25 measurement assembly.
  • ABB LS25 Receiver Unit – Optical receiver component paired with the LS25 transmitter for absorption measurement
Xem thêm
Ẩn bớt nội dung
Xem thêm
Ẩn bớt nội dung
Bạn hãy Đăng nhập để đánh giá sản phẩm này.
Xem thêm
Ẩn bớt nội dung

Bình luận

REM545BG229AABA REV:B REM545 Numerical Machine Protection Terminal
AO2000-LS25 In-Situ Laser Gas Analyzer Module

AO2000-LS25 In-Situ Laser Gas Analyzer Module

ABB EL3040 EasyLine Series Continuous Gas Analyzer

ABB EL3040 EasyLine Series Continuous Gas Analyzer

ABB EL3020 Industrial Continuous Gas Analyzer

ABB EL3020 Industrial Continuous Gas Analyzer

ABB SCC-F 31004G9B Gas Feed Unit

ABB SCC-F 31004G9B Gas Feed Unit

ABB SCC-C 23070-103112200000 Sample Gas Cooler

ABB SCC-C 23070-103112200000 Sample Gas Cooler

TSH210-Y0A2H11M2N4A13K1T1A6Y1C4C6M5 | ABB Straight Thermocouples SensyTemp