SUP-MPP1000 Multi-Parameter Analyzer
Giá (chưa VAT):
SUP-MPP1000 Multi-Parameter Analyzer
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.
Characteristics
Integrated design: Easy installation, operation, and maintenance
Multi-parameter monitoring: turbidity, residual chlorine, pH, temperature, conductivity, dissolved oxygen, and ORP
High precision: Precision up to 0.1~1NTU of tap water, 0.001~0.1NTU for purified water
Self-protection: Built-in ingress detection and automatic protection to avoid accidental damage
Easy integration: Standard RS-485 Modbus-RTU protocol and remote data transmission
High availability: Suitable for a variety of outdoor measurements in cold and hot areas
High customization: Support unique customizations, including trademark, name, and cabinet appearance
PH /ORP: 0-14pH, ±2000mV
Turbidity: 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU
Conductivity: 0-2000uS/cm / 0~20mS/m
Dissolved oxygen: 0-20mg/L
-
Introduction
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.
-
Specification
| Item | Index | Value |
| System | working power | (220±22)VAC, (50±1)Hz |
| Power | 30W | |
| Cabinet size | 800mm*506mm*180mm (standard version) | |
| Weight | about 15Kg | |
| Storage temperature | 4℃~+50℃ | |
| Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet flow | 500-1000 mL/min | |
| Inlet pressure | < 3kg/cm² | |
| Communication interface | RS-485 Modbus RTU communication protocol + wireless interface | |
| Display | 7-inch color touch screen, Chinese/English menu | |
| Turbidity | Measurement method | 90° light scattering method |
| Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-2000NTU | |
| Resolution | 0-1NTU / 0-20NTU / 0-100NTU:0.0001NTU | |
| 0-2000NTU:0.01NTU | ||
| Lower detection limit | 0.005 NTU | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 0-1NTU/0-20NTU/0-100NTU:2%or ±0.02NTU, whichever | |
| 0-2000NTU:10%or ±0.5NTU, whichever is greater | ||
| Repeatability | ≤1% | |
| Response time | ≤120s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide | Measurement method | Amperometric method/ polarography |
| Range | 0-5mg/L / 0-20mg/L | |
| Resolution | 0.01mg/L | |
| Lower detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| PH /ORP(optional) | Range | 0-14 pH, ±2000 mV (ORP) |
| Resolution | 0.01 pH, ±1 mV (ORP) | |
| Accuracy | ±0.1 pH, ±20 mV (ORP) or ±2% | |
| Repeatability | ±0.1 pH, ±10 mV (ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range |
-20℃ - 85℃
|
| Resolution | 0.1℃ | |
| Accuracy | ±0.5℃ | |
| Repeatability | ≤0.5℃ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 0-2000uS/cm |
| Pure water sensor: (0~20)uS/cm | ||
| Accuracy | ± 0.8% F.S pure water sensor: 3%F.S | |
| Repeatability | ≤0.4%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months | |
| Dissolved oxygen (Optional) | Range | 0-20mg/L |
| Accuracy | ±0.3mg/L | |
| Repeatability | ≤±1.5% | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 1-3 months | |
| Expansion port | Port type | RS485, 4-20mA |

HOME

Bình luận